Details | Last modification | View Log | RSS feed
Rev | Author | Line No. | Line |
---|---|---|---|
1 | - | 1 | || FILE: #0010.PLD |
2 | || PROJ: 20120608 |
||
3 | || PART: G16V8-#0010 |
||
4 | || |
||
5 | || DEV : GAL16V8 |
||
6 | || |
||
7 | || DESC: ACIA CONTROL |
||
8 | || |
||
9 | | |
||
10 | |GAL16V8A |
||
11 | | |
||
12 | || INPUT |
||
13 | | 1:DTR, 2:RS, 3:TRM, 4:PHI2, 5:WS, 6:ACIA, 7:EN, 8:RDY, 9:SE, 11:-, |
||
14 | || OUTPUT |
||
15 | | 12:G, 13:CS, 14:TA, 15:TB, 16:TXE, 17:J, 18:PHI2N, 19:K |
||
16 | | |
||
17 | || |
||
18 | | ACTIVE-LOW: G, CS, J, PHI2N |
||
19 | | |
||
20 | | PROPERTY: "SIMPLE" |
||
21 | | |
||
22 | | SIGNATURE: "0010 " |
||
23 | | |
||
24 | || -------------------------------------------------------- |
||
25 | || ABILITA TX RS485 |
||
26 | | TXE = (RS' & DTR') |
||
27 | | TA = TRM |
||
28 | | TB = TRM |
||
29 | || |
||
30 | || -------------------------------------------------------- |
||
31 | || -------------------------------------------------------- |
||
32 | || SEGNALI COMANDO FLIP-FLOP WAIT |
||
33 | | PHI2N = PHI2 |
||
34 | || ABILITAZIONE WAIT |
||
35 | | WTX = (ACIA' & WS') |
||
36 | || COMANDO J,K |
||
37 | | DATA = (RDY # WTX') |
||
38 | | J = DATA |
||
39 | | K = DATA |
||
40 | || |
||
41 | || -------------------------------------------------------- |
||
42 | | ACIAA = (ACIA' & WS & PHI2) || NO WAIT |
||
43 | | ACIAB = (ACIA' & WS' & EN) || WAIT |
||
44 | | CS = (ACIAA # ACIAB) |
||
45 | || |
||
46 | || -------------------------------------------------------- |
||
47 | | GX = (ACIA' & SE) |
||
48 | | GA = (ACIAA & SE') |
||
49 | | GB = (ACIAB & SE') |
||
50 | | G = (GX # GA # GB) |